Other part numbers are available to order but are not currently in stock. Use of the, instrument in a manner not prescribed herein may compromise, the product's functions and the protection features inherent in, the device. 1. equipment and devices that ensure personnel safety. When the upper display is showing a parameter and, Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. I want to use it as a display. Also, YOKOGAWA Electric Corporation assumes no liability for the customer's, failure to comply with these requirements. RS-485 interface allows to connect up to 30 devices with one remote master unit. The Yokogawa TC10-L limit controller is an FM-approved limit controller that can be configured either as a high limit or as a low limit controller by a user. There is minimum vibrations and no impact; 4. Can I hide the SP display? countries or regions where wiring will be installed. Do I need a minus sign ( - ) on the alarm setting value? - As a safety measure, always install a circuit breaker (an IEC 60947, compatible product, 5 A, 100 V or 220 V AC) in an easily accessible, location near the instrument. For supply connections use No. There are no water or other fluids (i.e. use only, in an electrical panel which encloses the rear housing. Temperature drift: It is part of the global accuracy; Operating temperature: 0 to 50C (32 to 122F); Storage temperature: -20 to +70C (-4 to +158F); Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. 2.Every change of the SEnS parameter will produces a change of the related parameter and in particular: [11] Ao1L and [12] Ao1H (when the analog retransmission is present) will be forced to the Ex.Range limits. When the maximum front protection (IP65) is. Safety, Protection and Modification of the Product, - In order to protect the system controlled by this product and the, product itself, and to ensure safe operation, observe the safety, precautions described in the Engineering manual. Backed by the high reliability and quality that Yokogawa has cultivated over many years. D + D - D + D - D + D - D + D - RS-485 5 6 The /GK suffix code means it comes with a panel gasket. 2.It is possible to set a initial scale read-out higher than the full scale read-out in order to obtain a reverse read-out scaling. Note: Every change of the dP parameter setting will produce. 4. 2.56 in min. The UT55A and UT52A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. The short depth of the controller helps save instrument panel space. The conguration parameters are collected in various groups. On burnout, it will be 0 mA. 0 mA = 0 mBar and 20 mA = -1000 mBar (vacuum). There are no water or other fluids (i.e. - Install the power cable keeping a distance of more than 1 cm from, - The power cable is required to meet the IEC standards concerned or the. Looking for more information on our people, technology and solutions? about the controller use can be found in the Engineering Manual: IM 05C01E81-12EN and the Communication Manual: IM 05C01E81-13EN. TC10 does not come with a terminal cover. Also, YOKOGAWA Electric Corporation assumes no liability for the customer's, failure to comply with these requirements. The shallow depth of the controller helps to save instrument panel space. : set points, proportional band, etc.). Clamp meters use wide jaws that clamp around the outside of an electrical conductor to provide non-contact current measurements. A reinforced isolation must be assured by the external solid state relays. Note: For TC wiring use proper compensating cable preferable shielded. Pay attention to the line resistance; a high line resistance may cause measurement errors. The. The TC series of temperature controllers is perfect for controlling the heating temperature of sealing parts and the temperature of sealing rolls (pre-heating) in a variety of different wrapping machinery. - For control relay output, alarm relay output, and power terminal, -N o C o o o D o F Temperature Controller, The TC10-N can be easily configured by the "Code Configuration" method for the most common requirements, just entering two 4-digit. Safety, Protection, and Modification of the Product, - In order to protect the system controlled by this product and the, product itself, and to ensure safe operation, observe the safety, precautions described in the Engineering manual. I'm looking for a replacement for the UD310. All information about. Related Manuals for YOKOGAWA TC10-L . . The instrument have one complete parameter set. Note: The resistance of the 3 wires must be the same. 2.2.2TD Pt 100 Input 1R The relative humidity is in accordance with the instrument, The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - Digital Input (DI2) connecting a free of. Notes: 1. The UT55A/UT52A also support open networks such as Ethernet communication. Sometime, e.g. What is the measured current of the TC10's RTD input? Looking for more information on our people, technology and solutions? Input impedance:> 1 M. TC10-L is capable of a retransmission output and up to two alarm outputs. The TC10 is a compact temperature single loop controller with easy -to-read 3 dynamic colors led display. The short depth of the controller helps save instrument panel space. The output (OUT) display lamp is lit. Can't find your region? 1. For measurements performed in the building instal-, For measurements performed at the source of the, - Wiring work must be carried out by a person with basic electrical, - Be sure to turn OFF the power supply to the controller before wiring, to avoid an electric shock. Before connecting the output actuators, we recommend to congure the parameters to suit your application (e.g. Can't find your region? : 500W. requirements of the area in which the instrument is being installed. Assign OP4 to the control output operation. terminal 1 and 2 to transmitter signal output. The EU Declaration of Conformity and the manual of the controller. 2. suit your application (e.g. V output: 0/2 10 V, galvanically isolated, RL min. At this point you can set the operator. exposed terminals and wiring on the back. be downloaded (free of charge) from the web-site: The Authorised Representative for this product in the EEA is: Viale Indipendenza 56, 27029 Vigevano (PV) - ITALY, The following general safety precautions must be observed during. Digital indicating controllers (476 pages), Program temperature controller (37 pages), Temperature measurement module (44 pages), Manual will be automatically added to "My Manuals", Temperature Controller YOKOGAWA TC10 Engineering Manual, Temperature Controller Yokogawa TC10 Quick Manual, Temperature Controller YOKOGAWA TC User Manual, Temperature Controller YOKOGAWA UT55A User Manual, Temperature Controller YOKOGAWA UP150 User Manual, Temperature Controller YOKOGAWA XS550 User Manual, Temperature Controller YOKOGAWA UT130 Technical Information, Temperature Controller YOKOGAWA UT150 User Manual, Temperature Controller YOKOGAWA UT100 Series User Manual. codes: Cod1 [LMNO] for the Input Type and Control Mode selection and Cod2 [PQRS] for the Alarms and the Service Functions. Model: TC10-L Quick Guide . Can I output in the 100% direction (20 mA or more) upon burnout? The Declaration of Conformity and the manual of the controller can. countries or regions where wiring will be installed. (24 VAC/DC), 6.0 VA max. Relay output 2,3: 2A, 250 V AC, resistive load. values and the controller output instantaneous value. The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the maximum temperature reached. The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to . There is minimum vibrations and no impact; 4. The Yokogawa TC10-L limit controller is an FM-approved limit controller that can be configured either as a high limit or as a low limit controller by a user. Wattmeter power consumption is the estimated hourly, energy consumption (using Load Voltage and Load Current, parameter values), computed on the previous 15 minutes. There are no water or other fluids (i.e. It has been de-, signed with compliance to the European Directives. For measurements performed in the building instal-, For measurements performed at the source of the, - Wiring work must be carried out by a person with basic electrical, - Be sure to turn OFF the power supply to the controller before wiring, to avoid an electric shock. 18 months (a year and a half) after shipment from the factory. Use a tester or similar device to ensure. all phases of operation, service and repair of this instrument. - Wiring should be installed to conform to NEC (National Electrical, Code: ANSI/NFPA-70) or the wiring construction standards in. IP65 Certification when the optional panel gasket is mounted. Current availability for non-stock parts is "Usually ships in 7-10 business days". Yokogawa Electric Corporation - TC10 - ENGINEERING MANUAL - PAG. - As a safety measure, always install a circuit breaker (an IEC 60947, compatible product, 5 A, 100 V or 220 V AC) in an easily accessible, location near the instrument. (63% response when the input changes from 10% 90%). voltage contact between terminals 4 and 16; - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. WARNING! can be downloaded (free of charge) from the web-site: The Authorised Representative for this product in the EEA is: Yokogawa Europe BV (Address: Euroweg 2 , 3825 HD Amersfoort, The Netherlands) is the Authorised Representative of. To protect the AL2 and AL3 thresholds against, undesired changes, they are available only at "Parameters, list" level (password: 20). the controller use can be found in the Engineering Manual: IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN. Are the TC10s wiring terminals screw terminals? all phases of operation, service and repair of this instrument. Yes, by changing the DP setting from 0 to 1. facilities, aviation facilities, and medical equipment. 3.When a shielded cable is used, it should be connected at one point only. Pt 1000 calibration: According to EN 60751/A2. The TC10-L supports easy configuration for a quick start-up, and it is configurable as a high limit or low limit controller. Do not run input wires together with power cables. The short depth of the controller helps save instrument panel space. NOTE: This parameter will be shown only when a linear input has been selected (mV, V or mA). The readout is updated every 15 minutes. With thermocouple K input, can I display digits after the decimal point for the temperature? When you do this, the upper limit range of 1000C becomes 999.9C. [34] r.md equal to 1(Limit output is de-energized at power on in any cases. [13] AL1 and [30] AL2 will be forced to : for an absolute maximum alarm, them will be forced to the maximum input span, for an absolute minimum alarm, them will be forced to the minimum input span, for all other alarm, them will be forced to zero, [14] HAL1 and [31] HAL2 will be forced equal to the 0.5% of the input span, [35] HYS will be forced equal to 0.05 % of the input span, the CAL group will be reset [51]A.L.P, [52] A.L.O, [53] A.H.P, [54] A.H.O, Upload manuals that we do not have and get. Products and components that are subject to wear due to conditions. A long press allows you to close the conguration parameter procedure (the instrument will come back to the standard display). There is minimum vibrations and no impact; There are no water or other uids (i.e. What is the /GK suffix code for the TC10? , we recommend to congure the parameters to. user must refer to the Engineering manual for special instructions. The UT75A also support open networks such as Ethernet communication. The UT52A/MDL supports 920 MHz band wireless communication. Input impedance: > 1 MW for mV Input 500 kW for Volt Input. If so used, it is the user's responsibility to include in the system additional. For SSR, mA and V outputs if the line length is longer than 30 m use a shielded wire. and workmanship for 18 months from the date of manufacturing. Enter your email address and check your inbox. 1.Do not run input wires together with power cables. Notes: 1. Supply Voltage: 100 to 240 VAC (-15 to +10%). Pay attention to the line resistance; a high line resistance, Digital indicating controllers (476 pages), Program temperature controller (37 pages), Temperature measurement module (44 pages), Manual will be automatically added to "My Manuals", Keyboard Functions During Parameter Changing, Factory Reset - Default Parameters Loading Procedure, How to See but Not Modify "Limited Access Parameters", Keyboard Function When the Instrument Is in Auto Mode, Temperature Controller YOKOGAWA TC10 Quick Manual, Temperature Controller Yokogawa TC10 Quick Manual, Temperature Controller YOKOGAWA TC User Manual, Temperature Controller YOKOGAWA UT55A User Manual, Temperature Controller YOKOGAWA UP150 User Manual, Temperature Controller YOKOGAWA XS550 User Manual, Temperature Controller YOKOGAWA UT130 Technical Information, Temperature Controller YOKOGAWA UT150 User Manual, Temperature Controller YOKOGAWA UT100 Series User Manual. Approximately 2 seconds or less. - For control relay output, alarm relay output, and power terminal, L H C o R o D o F /GK Temperature Controller, NOTE about the structure of this document, The usual installation sequence is the reverse of the operator, During installation, the first step is the wiring procedure followed, by the complete configuration. The equipment wholly protected by double insulation or, - Whenever a failure or a malfunction of the device may cause dan-, gerous situations for persons, things or animals, please remember, that the plant must be equipped with additional devices which, - We warrant that the products will be free from defects in material. When using an external power supply with 2-wire wiring of TC10, what is the input resistance when inputting 4-20 mA? If applicable, a timer count control monitors the amount of time outside the setpoint and registers the maximum temperature reached. 2. We assume no liability for safety, or responsibility for, the product's quality, performance or functionality should users. Notes: 1. 18 months (a year and a half) after shipment from the factory. . condensation); 5. Can you issue a TC10 calibration certificate? It has been de- signed with compliance to the European Directives. 1.Push the button for more than 3 seconds. If this instrument is used in a manner not specified in this manual. The UT35A and UT32A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. When installing the TC10, what is the depth in millimeters from the surface of the panel?